Blogs

02
Aug 2024

Decoding USP Standards - An In-Depth Look at USP <382>

Decoding-USP-Standards-An-In-Depth-Look-at-USP382

The safety and efficacy of injectable medications rely heavily on the integrity of their packaging. Container closure integrity testing (CCIT) ensures that vials, syringes, and other containers can effectively shield the drug product from contamination and maintain its sterility throughout its shelf life.

What is USP <382>?

Unlike its predecessor, USP, which focused on individual testing of elastomeric materials, USP <382> adopts a holistic approach. It emphasizes testing the functionality of the entire packaging system, including the elastomeric components (closures, stoppers, plungers) integrated with the container (syringe, vial, cartridge). This ensures the elastomeric components perform as intended within the specific packaging system they're designed for.

Published in December 2020, USP introduces a new set of requirements for assessing the functionality of elastomeric closures, stoppers, and plungers used in injectable drug delivery systems. These closures play a critical role:

  • Protection: They safeguard the drug product from external contaminants like microbes and moisture.
  • Containment: They prevent leakage of the medication during storage and transportation.
  • Safe Access: They enable controlled delivery of the drug through needles or spikes without compromising sterility

USP supersedes the functionality testing portion of the previous standard, USP. This new standard places greater emphasis on ensuring that elastomeric components function as intended throughout the lifecycle of the drug product. The compliance deadline of December 1st, 2025, marks a crucial milestone, compelling pharmaceutical companies to recalibrate their practices concerning Container Closure Integrity Testing

Package integrity testing is a crucial step in the development and manufacturing of injectable drugs. These tests evaluate the ability of the packaging system to maintain a sterile barrier and prevent product contamination. USP outlines specific testing methodologies for various aspects of elastomeric component functionality, including:

  • Fragmentation: This test assesses the closure's tendency to break into small particles during needle penetration, which could contaminate the drug product.
  • Penetration Force: It measures the amount of force required to pierce the closure with a needle or spike, ensuring ease of access for medication administration while safeguarding against accidental punctures.
  • Self-Sealing Capacity: This test evaluates the closure's ability to reseal itself after a needle or spike is withdrawn, preventing leakage and maintaining sterility.

Advanced Technologies for Enhanced Package Integrity

Manufacturers are constantly innovating and adopting advanced technologies to ensure robust CCI and meet the demands of USP. These advancements include:

  • Non-destructive testing methods: Techniques like ultrasonic testing and laser-based analysis allow for evaluation of closure integrity without damaging the packaging system.
  • Material science advancements: Development of new elastomeric materials with improved strength, elasticity, and resealing properties enhances the functionality of closures.
  • In-line monitoring systems: Integrating real-time monitoring during the manufacturing process helps identify potential defects and ensure consistent quality of elastomeric components.

The implementation of USP signifies a significant step forward in ensuring the safety and efficacy of injectable medications. By establishing stricter guidelines for CCI testing of elastomeric components, this standard fosters the development of robust and reliable packaging systems for parenteral drug delivery. Continuous advancements in testing methodologies and materials science will further strengthen container closure integrity and contribute to the delivery of high-quality injectable medications.

Readmore...
ccit, package integrity testing, container closure integrity testing, USP 382
6868

Popular Blogs

Tags

How to Leak Test High Risk Medical Device Packages

Jan 25, 2022   |   9247

Medical device leak testing is considered a critical step in ensuring package integrity primarily due to its sensitive nature. Leaks in the device can cause serious health risks to the patients and result in huge financial losses to the manufacturer. PTI's Seal-Scan technology is a non-destructive seal quality inspection technique for high risk pharmaceuticals and medical devices.

A Closer Look at PTI's Advanced Testing Services

Jun 27, 2024   |   7793

PTI offers advanced lab testing services across industries, safeguarding product integrity, safety, and regulatory adherence. Their expertise spans feasibility studies, test method development, stability testing, recall & batch release, and helium testing, all conducted by qualified professionals using advanced technologies.

Helium Leak Testing for Pharmaceuticals - PTI Offers Unmatched Solutions

Jul 15, 2024   |   7047

PTI offers unparalleled helium leak testing solutions for pharmaceutical packaging integrity. Our advanced services ensure high sensitivity and non-destructive testing, safeguarding product sterility and efficacy.

Decoding USP Standards - An In-Depth Look at USP <382>

Aug 02, 2024   |   6868

USP <382> sets new standards for assessing the functionality of elastomeric components in injectable drug packaging, emphasizing comprehensive container closure integrity testing to ensure safety and efficacy. Compliance by December 2025 is critical for pharmaceutical companies to maintain robust and reliable packaging systems.

Container Closure Integrity Testing (CCIT) - An Ideal Solution for the Pharmaceutical Industry

Sep 01, 2020   |   6602

Container Closure Integrity Testing is a method of leak detection using a non-destructive packaging inspection system to prevent possible contamination in pharmaceutical products.
ptiusa

Nos technologies sont conformes aux normes ASTM et autres normes r�glementaires.

Technologies d'emballage et inspection

PTI propose des systèmes d'inspection pour les tests d'étanchéité des emballages, l'intégrité des joints et les tests d'intégrité de la fermeture des conteneurs (CCIT). Nos technologies excluent la subjectivité des tests de colis et utilisent des méthodes de test conformes aux normes ASTM. Les technologies d'inspection de PTI sont des méthodes de test déterministes qui produisent des données quantitatives sur les résultats des tests. Nous sommes spécialisés dans l'offre d'une solution complète, y compris le développement de méthodes de test et la validation des équipements.

Contactez-nous

 

Technologies d'emballage et inspection

PTI propose des systèmes d'inspection pour les tests d'étanchéité des emballages, l'intégrité des joints et les tests d'intégrité de la fermeture des conteneurs (CCIT). Nos technologies excluent la subjectivité des tests de colis et utilisent des méthodes de test conformes aux normes ASTM. Les technologies d'inspection de PTI sont des méthodes de test déterministes qui produisent des données quantitatives sur les résultats des tests. Nous sommes spécialisés dans l'offre d'une solution complète, y compris le développement de méthodes de test et la validation des équipements.

ptiusa

Nos technologies sont conformes aux normes ASTM et autres normes r�glementaires.

Contactez-nous

 
Popup